D. Learning
Enable Learning: As shown in the figures down below, enabling this function allows learning
packets transmitted to the DUT before test packets are transmitted. If you disable this function, no
learning packets will be transmitted.
Frame Count: Repeat frame count per learning packets burst.
Frame Gap: Duration time between learning frames.
Delay Time After Learning: The time gap between after learning and the next process.
Tx Pkt Timeout: If the system fails to send the learning packet within the time you set in TxPKT
Timeout field, the packet will be drop.