Xtramus NuApps-MultiUnits-RM Ver1.5 Manual do Utilizador Página 110

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 253
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 109
D. Learning
Enable Learning: As shown in the figures down below, enabling this function allows learning
packets transmitted to the DUT before test packets are transmitted. If you disable this function, no
learning packets will be transmitted.
Frame Count: Repeat frame count per learning packets burst.
Frame Gap: Duration time between learning frames.
Delay Time After Learning: The time gap between after learning and the next process.
Tx Pkt Timeout: If the system fails to send the learning packet within the time you set in TxPKT
Timeout field, the packet will be drop.
110
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
Vista de página 109
1 2 ... 105 106 107 108 109 110 111 112 113 114 115 ... 252 253

Comentários a estes Manuais

Sem comentários