Xtramus MCS-2160 V1.9.2 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Xtramus MCS-2160 V1.9.2. Xtramus MCS-2160 V1.9.2 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - User’s Manual

MCS-2160 Media Converter User’s Manual USM Ver 1.9.2

Página 2 - Foreword

1.3. MCS-2160 Functions Overview 1.3.1. MCS-2160 Outer Case MCS-2160’s outer case consists two parts: Front Part and Back Part. The figure above sho

Página 3 - Revision History

1.3.2. MCS-2160 Front Part As mentioned in “1.3.1. MCS-2160 Outer Case”, MCS-2160 has 16 slots for installation of media converter module cards and 3

Página 4

1.3.3. Module Cards MCS-2160’s module cards can be divided into two categories: System Module Cards and Media Converter Module Cards. Module Card Ty

Página 5

1.3.3.1. System Module Cards A. System Module Card – XC-SFAN The XC-SFAN comes with your MCS-2160 chassis, and shall be installed on the Fan slot lo

Página 6 - Table of Contents

B. System Module Card – XM-M667 The XC-M667 comes with your MCS-2160 chassis, and shall be installed on the Mgm slot located on the far right side o

Página 7

C. System Module Card – XC-CASC The XC-CASC comes with your MCS-2160 chassis, and shall be installed on the Casc slot located on the right s

Página 8 - 1. MCS-2160 Overview

1.3.3.2. Media Converter Module Cards A. Media Converter Module Card – XC-7S81 XC-7S81 Front Panel Specification Port A RJ45 InterfacePort B SFP Dat

Página 9

B. Media Converter Module Card – XC-8S22 XC-8S22 Front Panel Specification Port A SFP+ InterfacePort B SFP+ Data Transfer Rate 10Gbps Ethernet Mode

Página 10 - XTRAMUS TECHNOLOGIES

C. Media Converter Module Card – XC-8S23 XC-8S23 Front Panel Specification Port A SFP+ InterfacePort B XFP Data Transfer Rate 10Gbps Ethernet Mode 1

Página 11

D. Media Converter Module Card – XC-8S33 XC-8S33 Front Panel Specification Port A XFP InterfacePort B XFP Data Transfer Rate 10Gbps Ethernet Mode 10

Página 12

Foreword Copyright Copyright © 2013 Xtramus Technologies, all rights reserved. The information contained in this document is the property of Xtramus

Página 13

E. Media Converter Module Card – XC-8S82 XC-8S82 Front Panel Specification Port A RJ45 InterfacePort B SFP+ Data Transfer Rate 10Gbps Ethernet Mode

Página 14

F. Media Converter Module Card – XC-8S83 XC-8S83 Front Panel Specification Port A XFP InterfacePort B XFP Data Transfer Rate 10Gbps Ethernet Mode 10

Página 15

1.3.4. MCS-2160 Rear End As mentioned in “1.3.1. MCS-2160 Outer Case”, MCS-2160’s rear end includes 3 different slots for installation of a DC module

Página 16

A. XC-RFAN Fan Module The XC-RFAN consists of two fans as shown in the figure below. After installing XC-RFAN, the Management Web Page will show the

Página 17

C. XCP-AC-300 XCP-AC-300 is a power module providing power source of 300W AC Redundant SPS (Vin 90~240VAC). The Power Jack of XCP-AC-300 is Male IEC

Página 18

1.3.5. Optional Fan Tray – MCS-FANT-05 Set MCS-FANT-05 on the base of MCS-2160, with dimension of 441 mm x 310 mm x 29 mm. XC-SFAN’s Port A and Po

Página 19

MCS-FANT contains LEDs that represent its ten fans. The figure down below shows how these fans are numbered. 26E-mail: [email protected]:

Página 20

2. MCS-2160 Installation MCS-2160 is a chassis with 16 slots for installation of media converter modules. Installing MCS-2160 is very easy and simp

Página 21

2.1.2. 10GBASE-R (Optical Fiber) 10GBASE-R is 10Gbps Ethernet connection that based on IEEE802.3ae. It uses fiber as transmission media with differ

Página 22

Optical Fiber As mentioned above, there are Single-mode and Multi-mode optical fiber. Both of them can be used for XC media converter module series.

Página 23

Revision History Date Version History 2011/10/11 1.0 First draft version 2011/11/04 1.1 1. Modifying XC-M667 figure. (Page 12) 2. Added new fig

Página 24

2.2. Hardware Installation Please follow the steps shown below for a better understanding on how to install hardware in MCS-2160. 2.2.1. Bracket inst

Página 25

Steps for installing a Bracket in MCS-2160 After attaching the Bracket’s Latch on the internal face of Chassis’ Latch, let this point be a fix cen

Página 26

2.2.2. Module Cards Installation Steps for installing a Media Converter Module Card in MCS-2160 Aim the border side of a Media converter Module Card

Página 27 - 2. MCS-2160 Installation

Steps for installing a Media Converter Module Card in MCS-2160 Lock the Captive Screw into the MCS-2160 to fix the Module Card into MCS-2160. 2.2.

Página 28

2.2.3.2. XCP-AC-300 Steps for installing a XCP-AC-300 Installing a XCP-AC-300 into MCS-2160 is quite simple. First of all, attach the Power Module in

Página 29

2.2.4.2. XC-RFAN Steps for installing the XC-RFAN Installing the XC-RFAN is quite simple, just attach the XC-RFAN into the respective slot of MCS-216

Página 30 - 2.2. Hardware Installation

3. MCS-2160 Management You can configure MCS-2160’s settings and view statistics generated while performing media converting with MCS-2160 by connect

Página 31

3.1.1. Accessing MCS-2160 Management Webpage To access MCS-2160’s management webpage, please open your web browser, and type in MCS-2160’s default IP

Página 32

3.1.2. MCS-2160 Management Webpage – Overview MCS-2160 Management Webpage Overview A Setting Options The Setting Options contains options for MCS-

Página 33

3.1.3. MCS-2160 Management Webpage – System 3.1.3.1. System Information System Information displays MCS-2160’ system information including: System

Página 34

Date Version History 2012/04/23 1.5 2. Adding figures and description for MCM-W series Management’s Counter. (Page 49) 3. Adding description ab

Página 35

3.1.3.2. Fan Tray Information Fan Tray Information includes: Fan Tray Information Hardware Version Shows the Hardware version of your Fan Tray. Firm

Página 36 - 3. MCS-2160 Management

3.1.4. MCS-2160 Management Webpage – Management There are 11 options available for Management, which includes: • IP Settings: Allows you to set

Página 37

B. Syslog Settings Syslog Configuration Syslog Receiver IPYou may set your Syslog Receiver IP in this field. The default Syslog Receiver IP is 192.1

Página 38

On the Syslog Server option, choose the Configure Syslog Server to pop up 3CDaemon Configuration window. In this 3CDaemon Configuration window, you

Página 39

Click the Clear list option to delete all the records of Time/IP Address/Msg Type/Message of each module shown in the right field. Choose the View

Página 40

C. User Settings For issues regarding to system security, MCS-2160 has 2 different user security levels, which are: • Administrator: User with Ad

Página 41

D. SNMP Settings SNMP v1, v2 & v3 Settings Enable Enable or disable SNMP v1&v2’s function. Read CommunitySet read for public or private use.

Página 42

E. Time Settings System Time Setting Get Device Time Save the settings made from Set Device Time. Set Device Time Set your MCS-2160 date and time ma

Página 43

F. Mail Settings Mail Configuration Enable You can able or disable your MCS-2160 mail warning function.POP3 Server Address Sets your POP3 server add

Página 44

G. Safety Settings Safety Settings Enable You can able or disable the Safety Configuration function. Temperature threshold Your MCS-2160 will shut

Página 45

Date Version History 2012/06/05 1.8 1. Adding Link Loss Forwarding (LLF) function. (Page 9) 2. Adding Japanese and Korean Language description.

Página 46

I. Media Converter Management Above shows the Media Converter Management option interface. You can set the Media Converter of the same LAN of you

Página 47

If you click the Counter button as shown below, you will open the Counter screen of the Media Converter showing the Network Port Statistics: Pleas

Página 48

J. Chassis Management Choosing the Chassis Management option will pop up the Port State Overview screen as shown above. In here, you will find

Página 49

After installing a module card in one of the slot 2-17, it will modify the inserted slot as shown above. Initially, the port of the slot will show i

Página 50

Click the slot with the module card installed to show a table of options as shown above. Module Card Options Information Shows the Module Card inf

Página 51

a. Information Click the Information option to pop up the Card Information / License Information window as shown above. Card Information S/N Serial

Página 52

b. Port A/B DDMI Click the Port A/B DDMI option to access the interface showing the parameters of DDMI for Port A/B. Port A/B Digital Diagnostics Mo

Página 53

c. Counter Click the Counter to pop up the Port Counter Statistics window as shown above. The Port Counter Statistics can display statistics reports

Página 54

d. Upgrade Click the Upgrade option to pop up the window for Update Firmware and Update FPGA as shown above. Update F/W (Firmware) Browse… Click

Página 55

e. Power Control Click the Power Control option to pop up the Power Control window as shown below. Power Control Power Off Turns off the Module Card

Página 56

Table of Contents Foreword ...

Página 57

g. Port A/B Universal Stream Counter Click the Port A/B USC option to pop up Port A/B Universal Stream Counter window as shown below. Port A/B

Página 58

i. Module Card Options_XC-7S81 For XC-7S81 module card management function, it includes Port Configuration function. The XC-7S81 module card managem

Página 59

Clicking the Port Configuration button will pop up the interface shown below: Port Configuration_XC-7S81 Auto Negotiation Select this option to let

Página 60

K. Chassis Overview The Chassis Overview will display the parameters of all the MCS-2160’ slots, please refer to the figure above. If you click the

Página 61

3.1.5. MCS-2160 Management Webpage – Maintenance Four options are available in the Maintenance configuration webpage: Save Changes, Update F/W, Syst

Página 62

C. System Reboot System Reboot Reboot You can reboot MCS-2160 by clicking the “Reboot” button. Please note that all unsaved settings will be lost af

Página 63

3.2. Managing MCS-2160 with HyperTerminal MCS-2160 allows users to make system configurations and view test statistics/system information with Hyper

Página 64

3.2.1. HyperTerminal Settings for MCS-2160 After connecting the PC’s serial port to XC-M667’s Console Port via a 2.5mm Phone Jack to RS-232 cable, pl

Página 65

A. MCS-2160 HyperTerminal Command – system Command Descriptions – system chassis The system show chassis command allows you to view MCS-2160’s Fan T

Página 66

A. MCS-2160 HyperTerminal Command – system (Continue) Command Descriptions – system show Shows the status of snmp v1/v2/v3. readcommunity Type comman

Página 67

H. Configuration Settings ...49 I. Media Converter Mana

Página 68 - MGM_RTC_v1.1b003 or newest

A1. MCS-2160 HyperTerminal Command – system chassis Please type sys show chassis command to display the status of your MCS-2160 and XC module cards,

Página 69

While the system is updating your MCS-2160 or XC module cards’ firmware, the Tftpd32 software will pop up a progress bar as shown below: When the Tf

Página 70

B. MCS-2160 HyperTerminal Command – ip Command Descriptions – ip show The ip show command allows you to view information of MCS-2160’s IP configurati

Página 71

3.3 Managing MCS-2160 with Telnet 3.3.1. Telnet Settings for MCS-2160 Before setting Telnet for MCS-2160, please activate this service on your PC.

Página 72

A. MCS-2160 Telnet Command – system Command Descriptions – system chassis The system show allows you to view MCS-2160’s Fan Tray status, PCB/firmware

Página 73

A. MCS-2160 HyperTerminal Command – system (Continue) Command Descriptions – system show Shows the status of snmp v1/v2/v3. readcommunity Type comman

Página 74

A1. MCS-2160 HyperTerminal Command – system chassis When you cascade numerous MCS-2160, the number of total chassis cascaded will be shown as the fi

Página 75

B. MCS-2160 Telnet Command – ip Command Descriptions – ip show The ip show command allows you to view information of MCS-2160’s IP configuration. sta

Página 76

4. MCS-2160 General Specifications Model MCS-2160 Slot 16 Slots for Installing XC Series Module Cards Dimension 441 mm x 310 mm x 88 mm Temperature

Página 77

Note: Information and specifications contained in this document are subject to change without notice. All products and company names are trademarks

Página 78 - ¾ Storage: 0

1. MCS-2160 Overview 1.1. General Descriptions of MCS-2160 MCS-2160 media converter chassis is a complete and versatile solution for the applicatio

Página 79

1.2. Features, Key Advantages, and Main Applications of MCS-2160 Features ¾ Diversified interfaces including SFP, SFP+, UTP and XFP ¾ Supports 3R

Comentários a estes Manuais

Sem comentários